SMEAR II Data - Photosynthesis
This folder contains both raw chamber data and processed fluxes from the automated chamber setup. Data from the new closed soil chambers is located in Toheli.
The processed fluxes and environmental driving factors measured alongside the gas exchange, i.e. temperature inside the chamber, ambient temperature, PAR, UV radiation and atmospheric pressure. Also the system variables (sample flows, pressure drop in the sample lines) that are required for calculating gas exchange can be found in the same files.
Fluxes
The daily files are named as FlxYYMMDD.NNN,
YY year
MM month
DD day
NNN identifier for soil chamber (2 digits)
or shoot (1 or 3 digits)
Columns:
1 year
2 month
3 day
4 hour
5 min
6 hour (dec) 0.0 - 23.99 h
7 CO2 flux mg m-2 s-1 extrapolated
8 H20 flux mg m-2 s-1 extrapolated
9 CO2 flux mg m-2 s-1 averaged
10 H20 flux mg m-2 s-1 averaged
11 O3 flux mg m-2 s-1
12 NOX flux ng s-1
13 NO flux ng s-1
14 CO2 concentration g m-3, in cuvette temperature and ambient pressure
15 H2O concentration g m-3, in cuvette temperature and ambient pressure
16 NOX concentration µg m-3, in cuvette temperature and ambient pressure
17 NO concentration µg m-3, in cuvette temperature and ambient pressure
18 O3 concentration µg m-3, in cuvette temperature and ambient pressure
19 ambient temperature deg C
20 cuvette temperature deg C
21 PAR µmol m-2 s-1
22 PAR stddev µmol m-2 s-1
23 UVA W m-2
24 UVB W m-2
25 VPD Pa
26 air pressure hPa
27 CO2Subs g m-3, concentration in substitution air
28 H2OSubs g m-3, concentration in substitution air
-999 indicates missing or bad (or otherwise ignored) data.
H2O fluxes are available at request.